
From Dentures to All on X
Introduction.
In fully edentulous patients wearing complete dentures, digitally aligning the various records is a significant challenge. Because the denture covers most of the soft tissue structures typically used as anatomical references, including the residual ridges and, in the maxilla, a large portion of the palate, anatomy-based alignment alone becomes unreliable and unpredictable.
For this reason, we recommend a Dual Scan Protocol, in which the denture is scanned both intraorally and extra-orally, and the extraoral scan serves as the common reference for integrating all digital records.

Data Integration Principle.
In this protocol, no single record contains all the information required to design the definitive restoration.
-
The complete denture provides the esthetics, tooth position, and existing vertical dimension.
-
Photogrammetry provides the exact three-dimensional position of the implants and Multi-Unit Abutments.
-
The soft tissue scan provides the information required to design the intaglio surface of the final prosthesis.
Integrating these three datasets enables the design of a precise, functional, and highly predictable AOX restoration.
Required Digital Records.
For patients wearing complete dentures, the following records are recommended:
1. Denture scan with the prosthesis seated intraorally.
2. Extraoral denture scan.
3. Digital bite registration.
4. Intraoral scan of the soft tissues and scan bodies.
5. Photogrammetry record.
Clinical Protocol.
Step 2: Bite Registration.
With both dentures properly seated and stabilized in the patient's mouth, capture the digital bite registration.
Scanning Recommendations.
- Maintain the scanner tip approximately 2 mm away from the tooth surfaces.
- Ideally operate between 0° and 45° of angulation relative to the scanned surface.
Objective.
To record the patient's existing vertical dimension and maxillomandibular relationship.
Step 3: Extraoral Denture Scan.
Remove both dentures from the patient's mouth and perform a complete scan of each prosthesis.
The scan should include:
External Surface.
- A complete 360-degree capture of:
- Buccal surfaces.
- Lingual or palatal surfaces.
- Occlusal surfaces.
Internal Surface.
- A complete scan of the entire intaglio surface.
Objectives.
Internal Surface.
- Allows the generation of a digital soft tissue model (Digital Pour).
External Surface.
- Preserves all information related to tooth position and denture morphology.
- Provides common reference points for aligning the various digital records.
Step 4: Intraoral Scan of Soft Tissues and Scan Bodies.
After removing the dentures:
1. Place the scan bodies onto the Multi-Unit Abutments.
2. Perform a complete intraoral scan capturing:
- Scan bodies.
- Soft tissues.
- Peri-implant tissues.
Objective.
Accurately record the soft tissue anatomy needed for intaglio surface design and integration with implant position data.
Step 5: Photogrammetry.
Perform the photogrammetry protocol using the system preferred by the clinician or laboratory.
Objective.
To capture the exact three-dimensional position of the implants, ensuring precision and passive fit of the definitive restoration.
Digital Alignment Workflow.
Once all records have been acquired, the datasets are integrated as follows:
1. Denture Alignment
The extraoral denture scan is aligned with the intraoral denture scan using the prosthetic teeth and external denture surfaces as common reference points.
2. Soft Tissue Model Generation
The relined intaglio surface generates an accurate digital model of the patient's soft tissues.
3. Photogrammetry Integration
The photogrammetry record is incorporated to establish the precise position of the implants and Multi-Unit Abutments.
4. AOX Restoration Design
Finally, the following datasets are combined:
- Esthetics and vertical dimension from the denture.
- Soft tissue information from the intraoral scan.
- Implant position data from photogrammetry.
This integration enables the design of a fully digital and highly predictable AOX restoration.
Step 1: Relining the Complete Dentures.
Take the existing complete denture(s) and perform a reline using preferably:
-Medium-body PVS.
-Light-body PVS.
Verify that the denture is fully stable and properly seated before proceeding with the digital workflow.
Objective.
To obtain an accurate reproduction of the soft tissues while minimizing denture movement during data acquisition.
